To see accurate pricing, please choose your delivery country.
 
 
United States
£ GBP
All Shops

British Wildlife

8 issues per year 84 pages per issue Subscription only

British Wildlife is the leading natural history magazine in the UK, providing essential reading for both enthusiast and professional naturalists and wildlife conservationists. Published eight times a year, British Wildlife bridges the gap between popular writing and scientific literature through a combination of long-form articles, regular columns and reports, book reviews and letters.

Subscriptions from £33 per year

Conservation Land Management

4 issues per year 44 pages per issue Subscription only

Conservation Land Management (CLM) is a quarterly magazine that is widely regarded as essential reading for all who are involved in land management for nature conservation, across the British Isles. CLM includes long-form articles, events listings, publication reviews, new product information and updates, reports of conferences and letters.

Subscriptions from £26 per year
Wildlife Survey & Monitoring  Aquatic Survey & Monitoring  Water Testing  Water Testing Meters

Multi-Parameter Bench Photometer - HI-83300-02

Manufacturer: Hanna Instruments
  • Measure 37 water quality parameters
  • Easy to user interface
  • Compact
  • Use in the lab or in the field
Multi-Parameter Bench Photometer - HI-83300-02
Click to have a closer look
  • Multi-Parameter Bench Photometer - HI-83300-02 Not in stock: Usually dispatched within 4 days
    £1,500.00
    #248654
Price: £1,500.00
About this product Specification Customer reviews Related products Recommended products

About this product

This Multi-Parameter Benchtop Photometer measures up to 37 of the most important water quality parameters. The system is incredibly user-friendly with method selections and set up modes clearly displayed on the LCD screen. The measuring procedure for each method is also displayed on the LCD, taking the user through the process, step-by-step. A help button allows the user to view context sensitive help at any point during the measurement process. Automatic conversion of readings to other chemical forms eliminates confusion and contributes to overall ease of use.

Up to 1000 data points can be logged on the photometer and then transferred to a mass storage device or PC using a USB cable.The unit can run on mains power via the USB port or on the internal rechargeable lithium polymer battery for use in the field.

HI-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

From Aluminium to Zinc, the HI-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.

A digital pH electrode input allows the user to measure pH by a traditional glass electrode.

The HI-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.

Please note, photometers are supplied without reagents but they are available separately.

Specification

Measurement Channels: 5 X OPTICAL CHANNELS; 1 X SMART ELECTRODE CHANNEL (pH MEASUREMENT)
Absorbance Range: 0.000Abs-4.000Abs
Absorbance Resolution: 0.001 Abs
Absorbance Accuracy: ±0.003 Abs (at 1.000 Abs)
Absorbance Light Source: Light-emitting diode
Absorbance Bandpass Filter Bandwidth: 8nm
Absorbance Bandpass Filter Wavelength Accuracy: ±1.0nm
Light Detector: Silicon photocell
Cuvette Type: round, 24.6 mm diameter
Number of Methods: 128 max
pH Range: -2.00 to 16.00 pH (±1000mV)*
pH Resolution: 0.01 pH (0.01 mV)*
Temperature Compensation: ATC (-5.0 to 100.0°C;*)
Logging: 1000 readings (mixed photometer and electrode)
Display: 128 x 64 pixel B/W LCD with backlight
USB-A: (host) functions mass-storage host
USB-B: ( Device) Functions power input, mass-storage device
Battery Life: >500 Photometer measurements, or 50 hours of continuous pH measurement
Power supply: 5 VDC USB 2.0 power adapter/ type micro-B connector 3.7 VDC Li-polymer rechargeable battery, non-serviceable
Operating temperature: 0 to 50°C; 0 to 95% RH, non-condensing
Dimensions: 206 x 177 x 97mm
Weight: 1.0kg
Supplied with:sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

*Limits will be reduced to actual sensor limits

ABSORBANCE
Absorbance Range 0.000 to 4.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy +/-0.003Abs @ 1.000 Abs

ALKALINITY Reagents - HI-93755-01 (100 tests); HI-93755-03 (300 tests)
Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric method

ALUMINIUM Reagents - HI-93712-01 (100 tests); HI-93712-03 (300 tests)
Aluminium Range 0.00 to 1.00 mg/L (as Al3+)
Aluminium Resolution 0.01 mg/L
Aluminium Accuracy ±0.04 mg/L ±4% of reading
Aluminium Method Adaptation of the aluminon method

AMMONIA Reagents: HR - HI-93733-01 (100 tests); HI-93733-03 (300 tests)
MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests)
LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)
Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method

ANIONIC SURFACTANTS
Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution 0.01 mg/L
Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading
Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS.

BROMINE Reagents: HI-93716-01 (100 tests); HI-93716-03 (300 tests)
Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.

CALCIUM Reagents: HI-937521-01 (50 tests); HI-937521-03 (150 tests)
Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+) Seawater: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading Seawater: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method

CHLORIDE Reagents: HI-93753-01 (100 tests); HI-93753-03 (300 Tests)
Chloride Range 0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C

CHLORINE DIOXIDE Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.

CHLORINE Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine UHR Reagents: HI-95771-01 (100 tests); HI-95771-03 (300 tests)
Chlorine, Free and Total HR: HI-93734-01 (100 tests); HI-93734-03 (300 tests)
Chlorine, Free ULR: HI-95762-01 (100 tests); HI-95762-03 (300 tests)
Chlorine Total: HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L Ultra Low Range: 0.001 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) Ultra High Range: 0 to 500 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L; 0.001 mg/L; 1 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading Ultra High Range: ±3 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl

CHROMIUM, HEXAVALENT Reagents: HR - HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR - HI-93749-01 (100 tests); HI-93749-03 (300 tests)
Chromium, Hexavalent Range Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.

COLOUR, WATER
Colour, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Colour, Water Resolution 1 PCU
Colour, Water Accuracy ±10 PCU ±5% of reading
Colour, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.

COPPER Reagents: HR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper - HI-93702T - 01 (100 tests); HI-93702T-03 (300 tests)
LR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)
Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method

CYANURIC ACID Reagents: HI-93722-01 (100 tests); HI-93722-03 (300 tests)
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method

FLUORIDE Reagents: HR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)
LR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)
Fluoride Range Low Range: 0.00 to 2.00 mg/L (as F-) High range: 0.0 to 20.0 mg/L (as F-)
Fluoride Resolution 0.01 mg/L; 0.1 mg/L
Fluoride Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±0.5 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method

HARDNESS, CALCIUM Reagents: HI-93720-01 (100 tests); HI-93720-03 (300 tests)
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method

HARDNESS, MAGNESIUM Reagents: HI-93719-01 (100 tests); HI-93719-03 (300 tests)
Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method

HARDNESS, TOTAL Reagents: HR - HI-93735-02 (100 tests); MR - HI-93735-01 (100 tests); LR - HI-93735-00 (100 tests); HR MR &LR - HI-93735-0 (100 x 3 tests)
Hardness, Total Range Low Range: 0 to 250 mg/L (as CaCO3) Medium Range: 200 to 500 mg/L (as CaCO3) High Range: 400 to 750 mg/L (as CaCO3)
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range: ±5 mg/L ±4% of reading Medium Range: ±7 mg/L ±3% of reading High Range: ±10 mg/L ±2% of reading
Hardness, Total Method Adaptation of the EPA recommended method 130.1

HYDRAZINE Reagents: HI-93704-01 (100 tests); HI-93704-03 (300 tests)
Hydrazine Range 0 to 400 μg/L (as N2H4)
Hydrazine Resolution 1 μg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method

IODINE Reagents: HI-93718-01 (100 tests); HI-93718-03 (300 tests)
Iodine Range 0.0 to 12.5 mg/L (as I2)
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method

IRON Reagents: HR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)
LR - HI-93746-01 (50 tests); HI-93746-03 (150 tests)
Iron Range Low Range: 0.000 to 1.600 mg/L (as Fe) High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution 0.001 mg/L; 0.01 mg/L
Iron Accuracy Low Range: ±0.01 mg/L ±8% of reading High Range: ±0.04 mg/L ±2% of reading
Iron Method Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters

MAGNESIUM Reagents: HI-937520-01 (50 tests); HI-937520-03 (150 tests)
Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method

MANGANESE Reagents: HR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)
LR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)
Manganese Range Low Range: 0 to 300 µg/L (as Mn) High range: 0.0 to 20.0 mg/L (as Mn)
Manganese Resolution 1 µg/L; 0.1 mg/L
Manganese Accuracy Low Range: ±0.02 mg/L ±3% of reading High Range: ±0.3 mg/L ±5% of reading
Manganese Method Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method

MOLYBDENUM Reagents: HI-93730-01 (100 tests); HI-93730-03 (300 tests)
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method

NICKEL Reagents: HR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)
Nickel Range Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution 0.001 mg/L; 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method

NITRATE Reagents: HI-93728-01 (100 tests); HI-93728-03 (300 tests)
Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method

NITRITE Reagents: HR - HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR - HI-93707-01 (100 tests); HI-93707-03 (300 tests)
Nitrite Range Freshwater Low Range: 0 to 600 μg/L (as NO2--N) High Range: 0 to 150 mg/L (as NO2-) Seawater Ultra Low Range: 0 to 200 μg/L (as NO2--N)
Nitrite Resolution Freshwater: 1 μg/L; 1 mg/L Seawater: 1 μg/L
Nitrite Accuracy Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Seawater ±10 μg/L ±4% of reading
Nitrite Method Adaptation of the EPA Diazotization method 354.1

OXYGEN, DISSOLVED Reagents: HI-93732-01 (100 tests); HI-93732-03 (300 tests)
Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

OXYGEN, SCAVENGER
Oxygen, Scavenger Range 0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution 1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy ±5 μg/L ±5% of reading (DEHA)
Oxygen, Scavenger Method Adaptation of the iron reduction method

OZONE Reagents: HI-93757-01 (100 tests); HI-93757-03 (300 tests)
Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method

pH Reagents: HI-93710-01 (100 tests); HI-93710-03 (300 tests)
pH Range Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV

PHOSPHATE Reagents: HR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)
Phosphate Range Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L
Phosphate Accuracy Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

POTASSIUM Reagents: HI-93750-01 (100 tests); HI-93750-03 (300 tests)
Potassium Range 0.0 to 20.0 mg/L (as K)
Potassium Resolution 0.1 mg/L
Potassium Accuracy ±3.0 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method

SILICA Reagents: HR - HI-96770-01 (100 tests); HI-96770-03 (300 tests)
LR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)
Silica Range Low Range: 0.00 to 2.00 mg/L (as SiO2) High Range: 0 to 200 mg/L (as SiO2)
Silica Resolution 0.01 mg/L; 1 mg/L
Silica Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±1 mg/L ±5% of reading
Silica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2

SILVER Reagents: HI-93737-01 (50 tests); HI-93737-03 (150 tests)
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method

SULPHATE Reagents: HI-93751-01 (100 tests); HI-93751-03 (300 tests)
Sulphate Range 0 to 150 mg/L (as SO42-)
Sulphate Resolution 1 mg/L
Sulphate Accuracy ±5 mg/L ±3% of reading
Sulphate Method Turbidimetric - Sulphate is precipitated with barium chloride crystals

ZINC Reagents: HI-93731-01 (100 tests); HI-93731-03 (300 tests)
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method

Customer Reviews

Manufacturer: Hanna Instruments
  • Measure 37 water quality parameters
  • Easy to user interface
  • Compact
  • Use in the lab or in the field
Current promotions